Outputs are the things NERV turns on and off: arches, pumps, blowers, lights and the conveyor. Inputs are the things NERV reads: loops, eyes, the roller pulse and the stop buttons. Step 3 is the supplier's list, typed in or loaded from a spreadsheet.
What people do here
- For each output, type its number, name, station and kind, and tick whether it is in use. Only a conveyor output can stop the conveyor.
- For each input, type its number, name and kind, say what it does (entrance loop, conveyor stop and so on), whether it is normally open or normally closed, and its debounce.
- Pick each row's channel, like "Module A, relay 3", from the modules of step 2. A channel another row uses says so.
- Or press Load from a spreadsheet: download the template, fill it in, save it as a CSV file and pick it. You see every row that will load, every row that will not and why, before anything changes. Loading the same file twice adds nothing.
The check runs as you type, in plain words: "No conveyor output yet", "Two outputs called Presoak 1". A draft with problems is still kept; it just cannot be activated.
Safety
Every output keeps its own OFF, ON and AUTO switch on the panel. The stop buttons are wired, not programmed: the conveyor never runs while one is pressed, whatever this list says.
Where the numbers come from
Everything here is your draft site configuration. The check is the same one NERV runs before it activates a version, so the page and NERV never disagree about what is wrong.