Install: the hardware

The hardware is the set of relay and input modules in the panel. Each relay switches one output (an arch, a pump, a blower) and each input reads one switch, loop or eye. Step 2 lists the modules the way the panel is labelled, so every output and input can be given its wire in step 3.

What people do here

  1. Pick the family of modules the panel uses and press Use this family. Each family has a drawing, one sentence on what it is, and what you need for it.
  2. Press Add a module for each one: its short name as the panel label says it (A, B and so on), which module it is from the catalogue, its network address, which panel it is in, and its watchdog.
  3. Press Find it. The wash computer looks for the module and answers in words, like "Found: 16 relays" or "Not found: check the cable and the address."
  4. Watch the count at the bottom: how many relays and inputs you have against how many are in use. Keep a quarter of them spare, so the wash can add an arch later without a new module.

A module whose relays are rated below 2.5 A shows a warning: put a stronger relay between it and the equipment.

Safety

The watchdog turns every output off within 5 seconds when the wash computer stops talking to the module. Set it on the module itself, or use a watchdog relay in the panel. Find it only asks the module what it is; nothing is switched.

Where the numbers come from

The catalogue is NERV's own list of module families, with each maker's figures; ones not yet checked on a test bench say so. The counts come from the modules you list and the outputs and inputs marked in use. The step is ticked when every module is a catalogue module with an address, there are enough channels, and no channel is used twice.