Install: the hardware
The hardware is the set of relay and input modules in the panel. Each relay switches one output (an arch, a pump, a blower) and each input reads one switch, loop or eye. Step 2 lists the modules the way the panel is labelled, so every output and input can be given its wire in step 3.
What people do here
- Pick the family of modules the panel uses and press Use this family. Each family has a drawing, one sentence on what it is, and what you need for it.
- Press Add a module for each one: its short name as the panel label says it (A, B and so on), which module it is from the catalogue, its network address, which panel it is in, and its watchdog.
- Press Find it. The wash computer looks for the module and answers in words, like "Found: 16 relays" or "Not found: check the cable and the address."
- Watch the count at the bottom: how many relays and inputs you have against how many are in use. Keep a quarter of them spare, so the wash can add an arch later without a new module.
A module whose relays are rated below 2.5 A shows a warning: put a stronger relay between it and the equipment.
Safety
The watchdog turns every output off within 5 seconds when the wash computer stops talking to the module. Set it on the module itself, or use a watchdog relay in the panel. Find it only asks the module what it is; nothing is switched.
Where the numbers come from
The catalogue is NERV's own list of module families, with each maker's figures; ones not yet checked on a test bench say so. The counts come from the modules you list and the outputs and inputs marked in use. The step is ticked when every module is a catalogue module with an address, there are enough channels, and no channel is used twice.